- Home
- Strike First 10-lb Portable Carbon Dioxide (CO₂) Fire Extinguisher
Strike First 10-lb Portable Carbon Dioxide (CO₂) Fire Extinguisher
A 10 lb carbon dioxide extinguisher rated 10-B:C: clean, non-conductive, no residue, 12 seconds of discharge. Full overview ↓
- Goes in
- Data center
- Machine shop
- Electrical room
- UL rating
- 10-B:C
- Capacity
- 10 lb
- Range
- 6–12 ft
- Charged
- 28 lb
- Height
- 19¾ in
- Warranty
- 5 years
About this unit
What Strike First says about it.
Ordering more than a few?Fleets, franchises and job sites get line-item pricing.Description
Safeguard critical equipment with the Strike First 10lb Carbon Dioxide (CO2) Fire Extinguisher. Offering double the capacity of the standard model, this unit provides powerful, clean-agent protection for larger electrical panels, server rooms, and laboratories. It suppresses fires instantly without leaving residue, ensuring no collateral damage to sensitive electronics.
Key Features:
-
Clean Agent: Rated 10-B:C for effective suppression of flammable liquids and electrical fires with zero residue or cleanup.
-
Corrosion Resistant: Crafted with an industrial-strength aluminum cylinder and a durable polyester powder paint finish.
-
Heavy-Duty Build: Equipped with a chrome-plated solid brass valve, stainless steel handle/pull pin, and an impact-resistant discharge horn.
-
Certified Safety: USCG approved (Type B:C Size II with bracket), DOT approved cylinder, and NFPA 10 compliant.
-
Warranty: Backed by a 5-Year Manufacturer’s Warranty.
Specifications:
-
Model: SF-10CO2
-
Capacity: 10 lbs
-
Discharge Range: 6–12 ft
-
Discharge Time: 12 seconds
-
Temperature Range: -22°F to 120°F
-
Dimensions: 19.75" H x 11.75" W x 7" Dia.
Shipping and returns
Extinguishers are pressurized cylinders and ship by ground only, from U.S. stock, to the contiguous United States. Shipping is shown at checkout before you pay. Units are inspected before they leave; if one arrives damaged, photograph the carton and contact us within 48 hours.
Overview
What is the Strike First SF-10CO2?
The Strike First SF-10CO2 is a 10 lb carbon dioxide fire extinguisher rated 10-B:C for flammable liquids and gases and energized electrical equipment. CO₂ smothers the fire by displacing oxygen and then dissipates, leaving no powder or liquid behind, which is why it belongs near electrical panels, server racks, laboratory benches and machinery that cannot tolerate residue. It discharges for 12 seconds with a 6 to 12 ft range. The industrial-strength aluminum cylinder is DOT approved and powder coated, with a chrome-plated solid brass valve, stainless steel handles and pull pin, and an impact-resistant horn. It weighs 28 lb (12.7 kg) charged. Listed to ANSI/UL 154 and 711 and CAN/ULC-S503 and S508, NFPA 10 compliant, five-year Strike First warranty.
Figures from the Strike First product sheet and service manual for this model.
Specifications
Strike First SF-10CO2 specifications
| UL and ULC rating | 10-B:C |
|---|---|
| Capacity | 10 lb |
| Fire classes | B (flammable liquids and gases) and C (energized electrical) |
| USCG approval | Type B:C Size II, with the bracket listed on the label |
| Discharge time | 12 seconds |
|---|---|
| Range | 6–12 ft (1.8–3.7 m) |
| Height | 19¾ in (50.2 cm) |
|---|---|
| Width | 11¾ in (30 cm) |
| Diameter | 7 in (17.8 cm) |
| Weight, charged | 28 lb (12.7 kg) |
| Standard bracket | Wall / vehicle bracket |
|---|---|
| Optional brackets | HDVB-3 heavy duty |
| Wall hook | SF1015WH |
| Cylinder | Industrial strength aluminum, DOT approved |
|---|---|
| Finish | Super durable polyester powder paint, corrosion resistant |
| Valve | Chrome plated solid brass |
| Handles and pull pin | Stainless steel, with retaining chain |
| Horn | Impact resistant |
| Label | Color and bar coded for service |
| Agent | Carbon dioxide, over 99.9% (SDS) |
|---|
| Listings | ANSI/UL 154 and 711 (UL); CAN/ULC-S503 and S508 (ULC) |
|---|---|
| Compliance | NFPA 10; DOT approved cylinder |
| Temperature range | −22 °F to 120 °F (−30 °C to 49 °C) |
| Inspection | Monthly, per NFPA 10 and the Strike First service manual |
|---|---|
| Maintenance | Annually by certified personnel; weigh against the charge weight on the valve (10% tolerance) |
| Hydrostatic test | Every 5 years, to the pressure on the nameplate (3000 psi) |
| Warranty | 5 years from date of manufacture, defects in material and workmanship |
| Model number | SF-10CO2 |
|---|---|
| SKU as listed | SF10CO2A |
As published by Strike First Corporation on the product sheet, service manual and safety data sheet for this model. Dimensions are nominal.
Goes with it
Sizes, agents and brackets for the Strike First SF-10CO2
Other sizes
Pair with
Mounting
Brackets and hooks as listed on the Strike First product sheet for this model. Items marked by request are not stocked yet; ask and we quote them.
Documents
Strike First SF-10CO2 documents
- Carbon dioxide product sheetRatings, dimensions, USCG approvals and brackets for the four CO₂ models PDF
- Safety data sheet, carbon dioxideCarbon dioxide fire extinguishing agent (Air Liquide, Mar 2023) PDF
- CO2 service manualInspection, maintenance, recharge and 5-year hydrostatic test PDF
- Strike First catalogThe full Strike First line PDF
Current Strike First publications, hosted on ShopStrikeFirst.com so the links do not break.
Compared
Strike First SF-10CO2 against the SF-15CO2
| Specification | SF-10CO2This product$280.99 | SF-15CO2View $310.99 |
|---|---|---|
| UL and ULC rating | 10-B:C | 10-B:C |
| Capacity | 10 lb | 15 lb |
| Discharge time | 12 s | 17 s |
| Range | 6–12 ft | 6–12 ft |
| Height | 19¾ in | 26¼ in |
| Diameter | 7 in | 7 in |
| Weight, charged | 28 lb | 37 lb |
| USCG approval | Type B:C Size II | Type B:C Size II |
| Optional brackets | HDVB-3 | HDVB-3 |
| Warranty | 5 years | 5 years |
Both columns from the Strike First product sheets. Prices are today's store prices.
Questions
Strike First SF-10CO2 questions
Answered from the product sheet, the service manual and the safety data sheet, not a sales script.
Ask something else01What is the SF-10CO2 rated for?
10-B:C: Class B flammable liquids and gases and Class C energized electrical equipment. Carbon dioxide has no Class A rating, so pair it with an ABC unit for wood, paper and cloth in the same area.
02Why choose CO₂ over ABC dry chemical?
CO₂ leaves nothing behind. It puts out the fire by displacing oxygen and cooling, then dissipates, so there is no powder in switchgear, servers, lab equipment or food-processing machinery. The trade-off is a shorter range (6 to 12 ft) and no Class A rating.
03How long does the SF-10CO2 discharge?
The Strike First product sheet lists 12 seconds at a 6 to 12 ft range. The CO₂ service manual gives an approximate figure for each size; the product sheet is the current published value.
04Is it safe to use CO₂ in a small room?
Use it and leave. Strike First's service manual warns that carbon dioxide reduces the oxygen in an unventilated space such as a closet or small room, and that prolonged occupancy can cause loss of consciousness. The discharge is also extremely cold; hold the handle and horn grip, not the horn itself.
05How is the SF-10CO2 serviced?
Monthly inspection, annual maintenance that weighs the unit against the charge weight stamped on the valve (10% tolerance), and a hydrostatic test every 5 years to 3000 psi with a complete internal inspection, per the Strike First CO₂ service manual and NFPA 10. Only Strike First OEM parts keep the warranty and the UL and ULC listings.
06Is the SF-10CO2 listed for use in the United States?
Yes. It meets or exceeds ANSI/UL 154 and 711 and carries the CAN/ULC-S503 and S508 listing for Canada. The cylinder is DOT approved and the unit complies with NFPA 10.
07What is the warranty?
Strike First warrants its carbon dioxide extinguishers for five years from the date of manufacture against defects in material and workmanship.
08What is the difference between the 10 lb and 15 lb CO₂?
Both are rated 10-B:C with the same 6 to 12 ft range and the same 7 in cylinder diameter. The 15 lb SF-15CO2 discharges for 17 seconds instead of 12 and stands 26¼ in tall at 37 lb charged. Buy the seconds you need for the hazard, not the rating.